KFAS: Fanuc CNC Parts, Service, & Repair
Fanuc ALARM SV0600 aiSV-B AL-8
Alarm SV0600 Fanuc 0iF or 31iB and AL-8 on
aiSV-B means,
the DC link current in the servo amplifier is abnormal.
Cause and troubleshooting
(a) Remove the motor power leads from the servo amplifier and cancel the emergency stop.
<1> If no abnormal DC link current alarm condition has occurred
→ Go to (b).
<2> If an abnormal DC link current alarm condition has occurred in the amplifier.
→ Replace the servo amplifier..
(b) Remove the motor power leads from the servo amplifier and check the isolation between the U,
V, or W motor power lead and the PE.
<1> If the insulation is deteriorated
→ Go to (c).
<2> If the insulation is normal
→ Replace the servo amplifier.
(c) Disconnect the motor from its power leads, and check whether the insulation of the motor or
power leads is deteriorated.
<1> If the insulation of the motor is deteriorated
→ Replace the motor.
<2> If the insulation of any power lead is deteriorated
→ Replace the power lead.
A06B6240 aiSV-B B65515EN Maintenance Manual