SV0606 and SP9133 alarm on Fanuc 30iB and 0iF control with A06B-6200 series Alpha i-B amplifiers (Fanuc Manual B-65285EN)
Alarm Code 10 AL-10 on PSM i-B (SV0606, SP9113)
An abnormal condition has been detected in the
external cooling fan.
- Check the rotation of the external cooling fan of the PSM.
- Check that the external (radiator) cooling fan is correctly installed.
Check
that the heat sink/ radiator fins of the PSM is free from dust and contamination
and clean as necessary
- The control printed circuit board is not correctly attached.
If
the problem continues to persist after the above checks, Replace the Power Supply
Module.
Alpha i-B Power Supply Module EXTERNAL cooling fan list
A06B-6200-H011 (αiPS 11-B) A90L-0001-0576
A06B-6200-H015 (αiPS 15-B) A90L-0001-0576
A06B-6200-H026 (αiPS 26-B) A90L-0001-0577
A06B-6200-H030 (αiPS 30-B) A90L-0001-0577
A06B-6200-H037 (αiPS 37-B) A90L-0001-0577
A06B-6200-H055 (αiPS 55-B) A90L-0001-0577 Qty 2
©