Repair/ Return Option Also Available At $700.
SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME
$1,200 ($450
Exchange Credit Available)
Dimensions (H 380 x W 60 x D 172 mm)
Rated Input: 283-325VDC 0.75 kW
Rated Output Current: L axis 3.0 A
Fanuc A06B-6096-H101 is typically used with Fanuc motor a0.5/3000, a1/3000, a2/2000 and a3/3000
Related technical information Video
Alarm 368 369 Note Alarm 466 Note
A06B-6096-H101 Alarms Meaning and action to be taken
Alarm Meaning
1 Internal Fan Stopped (FAL)
2 Low control power voltage
(LV5V)
5 Low DC link voltage
(LVDC)
8 L-axis over-current
(HCL)
9 M-axis over-current
(HCM)
A N-axis over-current
(HCN)
b L
& M-axis over-current
C M
& N-axis over-current
d L
& N-axis over-current
E L, M, N -axis over-current
8. L-axis IPM alarm (IPML)
9. M-axis IPM alarm (IPMM)
A. N-axis IPM alarm (IPMN)
b. L
& M-axis IPM alarm
C. M
& N-axis IPM alarm
d. L
& N-axis IPM alarm
E.
L, M, N-axis IPM alarm
L
FSSB Disconnect COP10A
U
FSSB Disconnect COP10B
Related Part Numbers KFASLLC
kfasllc.com
A50L-0001-0273/A
A230-0526-X001/B
A230-0527-X001/A
A230-0527-X002
A20B-2100-0250 or A20B-2100-0540
A16B-2202-0740