KFAS: Fanuc CNC Parts & Repair
 

αi PS series

200-V input — power source regeneration type

Item / Modelαi PS 5.5αi PS 11αi PS 15αi PS 26αi PS 30αi PS 37αi PS 55
Power supply (Note 1)Main circuit200 to 240 VAC +10%, −15%, 3φ 50/60 Hz, ±1 Hz
Control power200 to 240 VAC +10%, −15%, 1φ 50/60 Hz, ±1 Hz
Power equipment capacityMain circuit9 kVA17 kVA22 kVA37 kVA44 kVA53 kVA79 kVA
Control power0.7 kVA
Rated output capacity (Note 2)6.8 kW13.2 kW17.5 kW29.8 kW35 kW43 kW65 kW
Control methodRegenerative control (power source generation)

Output capacities for motor selection

Item / Modelαi PS 5.5αi PS 11αi PS 15αi PS 26αi PS 30αi PS 37αi PS 55
Rated output capacity5.5 kW11 kW15 kW26 kW30 kW37 kW55 kW
Maximum output capacity13 kW24 kW34 kW48 kW64 kW84 kW125 kW
Peak maximum output capability22 kW38 kW51 kW73 kW85 kW106 kW192 kW

Output capacities for motor selection (A06B-6110-Hxxx)

Item / Modelαi PS 5.5αi PS 11αi PS 15αi PS 26αi PS 30αi PS 37αi PS 55
Maximum output capacity11 kW20 kW28 kW40 kW53 kW70 kW104 kW
Peak maximum output capability20 kW34 kW46 kW66 kW77 kW96 kW174 kW

200-V input — resister discharge type (αi PSR)

Item / Modelαi PSR 3αi PSR 5.5
Power supply (Note 1)Main circuit200 to 240 VAC +10%, −15%, 3φ 50/60 Hz, ±1 Hz
Control power200 to 240 VAC +10%, −15%, 1φ 50/60 Hz, ±1 Hz
Power equipment capacityMain circuit5 kVA12 kVA
Control power0.5 kVA
Rated output capacity (Note 2)3.8 kW9.4 kW
Control methodRegenerative control (resister discharge)

Output capacities for motor selection

Item / Modelαi PSR 3αi PSR 5.5
Rated output capacity3 kW7.5 kW
Maximum output capacity12 kW20 kW