Alpha Series Power Supply Module Alarm List (A06B-6077-Hxxx, A06B-6087-Hxxx) |
E-mail us
at service@kfasllc.com if you need
further assistance. |
|
Check
Price & Availability on PSM |
" " |
No LED Status display |
|
|
|
Check incoming AC 200V at
CX1A connector. |
|
|
|
Replace the PSM |
|
|
|
|
|
|
AL-01 |
Main circuit power module
(IPM) has detected an Error |
|
|
|
Check incoming 3 Phase Power. |
|
|
|
Replace the PSM |
|
|
|
|
|
|
AL-02 |
Internal cooling fan for
the PSM has stopped |
|
|
|
Check for contamination
around internal cooling fan. |
Fan for A06B-6077-Hxxx |
Fan for A06B-6087-Hxxx |
|
Replace internal cooling fan.
Send in PSM to us for Wash & Test. |
|
|
|
|
|
|
AL-03 |
Temperature inside the PSM
has risen abnormally |
|
|
|
Check the external cooling
fan on the heat-sink of PSM |
|
|
|
Send in the PSM to us for
Wash & Test service. |
|
|
|
|
|
|
AL-04 |
DC voltage at the DC Link
has dropped |
|
|
|
Check incoming 3 Phase Power.
Replace the PSM |
|
|
|
|
|
|
AL-05 |
PSM capacitor was not
recharged within the specified time |
|
|
|
Check incoming 3 Phase Power.
Replace the PSM |
|
|
|
|
|
|
AL-06 |
Input 3 Phase Power is
abnormal (open phase) |
|
|
|
Check incoming 3 Phase Power.
Replace the PSM |
|
|
|
|
|
|
AL-07 |
DC Voltage at the DC link
is abnormally high |
|
|
|
Check incoming 3 Phase Power.
Replace the PSM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|