KFAS is not affiliated with Fanuc, GE Fanuc. All trademarks are acknowledged.

  RS232 serial communication parameters for Fanuc 6 control  
Fanuc 6-TA and 6-MA controls  
Parameter 000 bit 5 = 1  
                 026 bit 7 = 0  Personal Computer Settings
                 002 bit 5 = 1   4800 Baudrate
                 024 bit 0 = 1 (for 2 stop bits)   2 stop bits
                                = 0 (for 1 stop bit)   ISO Code (ASCII)
Set Parameter 025 according to the following table  
Baud Rate 7 6 5 4 3 2 1 0
50 0 0 0 0 0 1 0 0
100 1 0 0 0 0 1 0 0
110 1 0 0 0 0 1 0 1
150 1 0 0 0 1 0 0 0
200 1 1 0 0 0 1 0 0
300 1 0 0 0 1 1 0 0
600 1 1 0 0 1 1 0 0
1200 1 1 0 0 1 1 1 0
2400 1 1 0 0 1 1 1 1
4800 1 1 1 0 1 1 1 1
9600 1 1 1 1 1 1 1 1
 
  Even parity
  Data length = 7 bits
  Control Codes (Xon/ Xoff used)
  LF for End Of Block
 
 
Jumper Pin Settings on the Puncher Interface PCB A20B-0007-0060 / 0061
S2 (B4) FACIT RS232C  
"9-8" *    
"10-7" *    
"11-6"      
"12-5"      
"13-4"   *  
"14-3"   *  
"15-2"      
"16-1"      
     
S3 (B5) FACIT RS232C  
"9-8" *    
"10-7" * *  
"11-6" * *  
"12-5" *    
"13-4"   *  
"14-3"      
"15-2"      
"16-1"   *  
     
 
 
Fanuc 6-TB and 6-MB controls (including level up controls)  
SETTING PAGE

 PUNCH CODE     = 1 (0:EIA 1:ISO)

INPUT DEVICE 1 = 0 (0:TAPE 1:RMT)

INPUT DEVICE 2 = 1 (1:RS232C)

PARAMETERS

 007 = 0XXXXXXX 6T

008 = 0XXXXXXX 6M

311 = 10011001 (for baud rate =4800, for others see table 1.1)

340 =        2

341 =        2

Table 1.1 Baud rate setting (Parameter 311)  
Baud Rate Bit 3  Bit 2 Bit 1 Bit 0  
50 0 0 0 0  
100 0 0 0 1  
110 0 0 1 0  
150 0 0 1 0  
200 0 1 0 0  
300 0 1 0 1  
600 0 1 1 0  
1200 0 1 1 1  
2400 1 0 0 0  
4800 1 0 0 1  
9600 1 0 1 0